Online information source for semiconductor professionals

Measurement of Metal Film Thickness for Copper Interconnects

Popular articles

Micron moving fast on Hynix in Q208 NAND flash rankings, says iSuppli - 19 August 2008

Numonyx to close California Technology Center - 12 August 2008

Qimonda starts major reorganization: exits PC DRAM market - 13 October 2008

Micron close to Inotera share purchase, says Gartner - 06 October 2008

Applied Materials sees higher CapEx spending for 2009 - 15 August 2008

DANIELE CONTESTABLE-GILKES, SAILESH M. MERCHANT & MINSEOK OH, Agere Systems, Orlando, FL, USA

ABSTRACT

Increased device speed and improved electromigration are two main drivers for the semiconductor industry’s transition from aluminium to copper for integrated circuit interconnects. A major disadvantage of copper is its fast diffusion rate into underlying substrates. Therefore, in order to benefit from the advantages of lower sheet resistance and improved electromigration by using copper, a high-quality, high-performance diffusion barrier is also necessary. Various transition and refractory metals, their alloys, silicides and nitrides, such as Ta and TaNx, prevent copper from diffusing into adjacent dielectrics. The deposition of the thin barrier layer, or barrier bilayers, is followed by the PVD or CVD deposition of a copper seed layer, which is a prerequisite for the subsequent bulk copper deposition by electroplating. This introduces a new metal stack into an already complicated integration scheme. Copper integration, along with decreasing device sizes, and the transition to 300-mm size wafers, provokes the need for accurate and reliable thickness measurements of the constituent films to monitor and maintain strict process control. Thus, the thickness of the barrier and seed layers, as well as the bulk of the electroplated copper must be accurately monitored to ensure a quality manufacturable process. This article describes a comparative study of several techniques used to measure layer thickness.

Download Please login to download the paper. No account yet? Please register. It's free!

Related jobs

Process Engineer R&D Solar - Applied Materials - Alzenau, 08 November 2007

Engineering/Tech Program Manager Sr - Applied Materials - Santa Clara, 07 November 2007

Embedded Control Systems HW & SW Engineer-Semiconductor Processing Equipment! - MKS Instruments, Inc. - Wilmington, 05 September 2007

Principal Embedded Software Engineer - MKS Instruments, Inc. - Wilmington, 05 September 2007

Senior Applications Engineer - Axcelis - Beverly, 09 August 2007

Related articles

All-Optical, Non-Contact Metrology for Characterising CMP of Copper Films - 01 March 2000

Fast, In-line Copper Metrology Using Optoacoustics - 01 March 2002

Tool Order: Asian memory manufacturer selects copper metrology tools from Rudolph - 06 March 2008

KLA-Tencor teams with Dainippon Screen to remove critical yield barriers to copper IC production… - 04 February 2005

Advanced measurements for photoresist fundamentals - 01 December 2004

Reader comments

I don't know much about this.I got an idea after reading this.Thanks for sharing! <a >dished ends</a>
By dished ends on 12 November 2008

Post your comment

Name:
Email:
Please enter the word you see in the image below: