Online information source for semiconductor professionals

New Product: Aerotech’s WaferMax T rotary stage offers form factor benefits

Popular articles

Micron moving fast on Hynix in Q208 NAND flash rankings, says iSuppli - 19 August 2008

Numonyx to close California Technology Center - 12 August 2008

Qimonda starts major reorganization: exits PC DRAM market - 13 October 2008

Micron close to Inotera share purchase, says Gartner - 06 October 2008

Applied Materials sees higher CapEx spending for 2009 - 15 August 2008

WaferMaxProduct Briefing Outline: Aerotech’s WaferMax T rotary stage was originally designed for the demands of precision wafer inspection; however, due to its low height design it can be used in a wider range of tool applications where high-throughput production performance with high levels of precision are required especially when space and access are limited. The WaferMax-T rotary stage has full 360-degree rotation and a certified accuracy of +/-5arc/sec.

Problem: WaferMax stages are well matched to applications requiring very tightly synchronized axis-to-axis and axis-to-sensor motion and where very accurate incremental steps must be combined with precise speed such as optical line scanning. The direct drive rotary is only 50mm tall, handling limited space environments with easy chuck integration.

Solution: A standard 25mm aperture allows for easy pass-through of vacuum lines where limited rotation is required. If continuous rotation is necessary, an optional single or dual port rotary union can be incorporated. The tabletop includes a standard mounting pattern that allows for easy wafer-chuck mounting. To maximize positioning performance, the WaferMax T utilizes Aerotech’s S-series brushless, slotless motor. This motor has all the advantages of a brushless direct-drive motor — no brushes to wear, no gear trains to maintain, and high acceleration and high speeds. Since it is a slotless, ironless design, there is zero cogging, meaning that there is no torque ripple. A 10,000-lines-per-revolution encoder results in 0.065 arc sec resolution. A 2048 line option is also available. The motor and high-performance rotary encoder are directly coupled to a common shaft.

Applications: WaferMax T is designed to handle contoured motion, smooth scan velocity, or precise incremental steppping. The low inertia and zero backlash make the WaferMax T suitable for applications requiring frequent directional changes. Combined load rating for WaferMax Z-Theta solutions is around 3kg, and, for applications beyond the recommended load, there are a number of vertical and rotary stage options that can be used.

Platform:
The WaferMax-T rotary stage has a thick-walled, precision ground shaft and high-stiffness angular contact bearings for improved wobble performance, high moment rigidity and reduced friction. With its directly coupled, high-accuracy rotary encoder, the stage will provide a working resolution of up to 0.065arc-sec with the 10,000-lines-per-revolution encoder option. WaferMax stages may be used on their own or in combination with other Aerotech submicron, linear x and y stages along with associated drives and motion controls.

Availability: Summer 2007 onwards.

WaferMax

Related jobs

Factory Start Up Director/Manager (Solar Factory Operations) - Applied Materials - , 07 August 2008

Quality Assurance Engineer - Tokyo Electron Limited - Santa Clara , 30 October 2007

Diffusion Engineer - AMI Semiconductor - Pocatello, 10 August 2007

Technical Support Engineer - Carl Zeiss SMT, Inc. - Peabody, 10 August 2007

Senior Applications Engineer - Axcelis - Beverly, 09 August 2007

Related articles

Optimized 300mm vacuum pumping requires an understanding of choices - 01 December 2004

New Product: Enhanced ferrofluid magnetic liquids from Ferrotec boost critical sealing applications - 29 August 2006

The Advantages of Using Short Cycle Time Manufacturing (SCM) Instead of Continuous Flow Manufacturin - 01 March 1999

New Product: Nikon’s NSR-S310F scanner extends dry ArF beyond 65 nm - 16 August 2007

Fan-Filter Unit (FFU) Test Procedures - 01 December 2002

Reader comments

No comments yet!

Post your comment

Name:
Email:
Please enter the word you see in the image below: