Product Briefing Outline: ASML has introduced the
‘TWINSCAN' XT:1900i. In combination with ASML proprietary low k1
capabilities, this new system is designed to extend optical immersion
lithography for volume production at the 40nm half-pitch dimensions
with an overlay specification of 6nm (SMO). ASML's newest 193-nm
wavelength immersion scanner uses a 1.35 NA inline catadioptric lens
assembly that is near the practical limit for water-based immersion
technology. ASML expects to begin shipping the XT:1900i by mid 2007.
Problem: The TWINSCAN platform was introduced in
2000 as critical wafer measurements proved a bottleneck to wafer
throughput in the litho cell. The TWINSCAN system's dual-stage
technology separates the process of wafer exposure from metrology and
performs both processes in parallel, while improving throughput by more
than 50 percent, according to the company. In parallel with
productivity improvements optical lithography has been pushed to
achieve imaging significantly below the wavelength of light.
Innovations in optical assemblies, polarization control have been
required for volume production applications. Using an immersion fluid
between the wafer and the lens enhances depth of focus (DOF) for a
given numerical aperture. Immersion also allows lens designs with
numerical apertures significantly larger than 1.0, therefore allowing
improved resolution.
Solution: ASML's
newest 193-nm wavelength immersion scanner uses a 1.35 NA inline
catadioptric lens assembly that is near the practical limit for
water-based immersion technology. The system employs an ultra-k1
package, consisting of QUASAR XL, LithoGuide ILIAS, DoseMapper, Reticle
Shape Correction, CDFEC and Focus Spot Monitor. The XT:1900i
illuminator features polarization at maximum throughput, and extremely
homogeneous pupil fill, that is adapted to ultra low-k1 pupil shapes.
Standard as well as customized illumination modes can be enhanced by
optimizing the polarization mode, to maximize the contrast and reducing
the mask error factor per application.
Applications: Patterning at the 40nm node and below.
Platform:
The TWINSCAN platform was introduced in 2000. The new XT:1900i is based
on ASM's previous generations of immersion lithography systems. The
XT:1900i uses the TWINSCAN platform's dual wafer stage functionality
for parallel dry metrology and wet exposure to achieve a claimed 131
wafers per hour (125 exposures).It will be using the ‘Starlith' 1900i
inline catadioptric lens system from Carl Zeiss SMT.
Availability: Mid 2007 onwards.