THOMAS EHMANN, LASZLO FABRY, JAMES MORELAND & JÜRGAN HAGE,Wacker Siltronic AG, Burghausen, Germany
MARIA SERWE, Agilent Technologies GmbH, Waldbronn, Germany

ABSTRACT

Crystalline perfection and cleanliness of silicon wafers are becoming limiting factors for increasing integration density of semiconductor devices. Both crystalline perfection and cleanliness of the wafers depend upon the cleanliness of process chemicals, process environment and process variations. Monitoring process hygiene requires sophisticated ultratrace microanalytical techniques that are capable to control process cleanliness and to assure product quality down to the lower ppt-range (pg/ml) [1,2]. As a rule of thumb, reference materials, analytical environment and analytical chemicals must be one order of magnitude cleaner than the process conditions to allow dependable analytical results on processes and products.

Download Please login to download the paper. No account yet? Please register. It's free!

Related jobs

Semiconductor Photo Line Maintenance Technician - AMI Semiconductor - Pocatello, 02 October 2007

Design Engineer/System Architect - AMI Semiconductor - POCATELLO, 10 August 2007

Diffusion Engineer - AMI Semiconductor - Pocatello, 10 August 2007

Analog IC Design Engineer - AMI Semiconductor - Austin, 10 August 2007

Analog Design Engineer - AMI Semiconductor - Sunnyvale, 10 August 2007

Related articles

Atomic Force Profilometry for Chemical Mechanical Polishing Metrology - 01 March 2000

Tribology issues in CMP - 01 March 2003

Tribology issues in CMP - 01 March 2006

The Impact of Conveyor Transports on Factory Performance at Infineon’s (Siemens) 200-mm Fab - 01 December 1999

Efficient Qualification of PFA Distribution Systems Using 0.49% HF and DI Water - 01 March 1999

Reader comments

No comments yet!

Post your comment

Name:
Email:
Please enter the word you see in the image below: